WA Triple Interceptors
Product Code | Capacity (L) | A (mm) | B (mm) | C (mm) | D (mm) | E (mm) | F (mm) | G (mm) | Mass (kg) |
---|---|---|---|---|---|---|---|---|---|
WATI1 | 760 | 2050 | 860 | 1370 | 550 | 750 | 800 | 650 | 500 |
WATI2 | 1000 | 2050 | 860 | 1370 | 700 | 600 | 650 | 500 | 500 |
WATI3 | 1500 | 2050 | 860 | 1670 | 1050 | 550 | 600 | 450 | 610 |
WATI4 | 2000 | 2050 | 860 | 1970 | 1400 | 500 | 550 | 400 | 720 |
Notes
- Tested and approved for installations up to 5000mm deep
- 300mm risers available
- Large range of concrete surrounds and gas tight covers to suit all load ratings
- MPa rating for GRC – 60 MPa @ 28 days
- Available extras:
- Step irons
- Support frame & work platforms for above ground installations.
- Other pipe sizes available upon request
- Fitted standard with PVC fittings. Other material (HDPE etc) available
- Installation instructions must be followed
- Cover will add to overall depth
- Internally coated with acid resistant tar epoxy paint.
- Confirm with local authority for suitability prior to purchase/install.
- Installation instructions must be followed.