Australia-wide sales enquiries | 1300 885 295

Australia-wide sales enquiries | 1300 885 295

Class A (installation)

Typical installation for pedestrian and pedal access for garden beds, landscaped and grass areas

Class A 330kg nominal wheel load
AS 3996-2606

cable-pits-class-A

Notes

  1. Approved for installations up to 5,000mm deep. Refer to note 5.
  2. GRC MPa rating to 60Mpa @ 28days
  3. When specific site conditions vary, consult design engineer/consultant
  4. Risers are available
  5. For installations in excess of 1,800mm deep, refer to special depth instructions: DWG No. GRCIISD
  6. Any depths beyond 900mm, step irons are required at 250mm intervals, or as specified
  7. For all pipe/conduit entries and riser joins, use Mascot’s two part epoxy
  8. For all further enquiries, contact Mascot on 1300 885 295

Drawing No: CPGRCIICA